Auto Parking Management Systems Warming Up Sliding Gate Operator Alarm Light Socket
Electronic Data
Model |
KMP202 |
Soft start |
YES |
Stop on an obstacle (sensitivity adjustable) |
YES |
Auto warming-up (at freezing temperature) |
YES |
Remote control |
418MHz (50m, approx) |
Wire control |
Available |
Auto closing |
YES |
Vehicle loop detector socket |
YES |
Photocell socket |
YES |
Alarm light socket |
YES |
Troubleshooting
I. The motor runs but the sliding gate operator doesn't work.
A: Check whether the clutch is closed.
2 The power indicator light doesn't flash and the key doesn't react.
A: Check whether power is connected right.
B: Check whether the fuse is burned, yes, please exchange it.
3 The opening and closing limit can not work.
A: Check whether the limit adjustment switch is installed right.
B: Check whether the limit iron is installed right. Adjust the position of the limit iron.
Remote Controller Coding
If the remote controller or the radio emitter doesn't match the code of the control panel, please adjust the code of the remote control to make them match.
Steps:
Reading the code:
The code is in the back of the remote control or the radio emitter. Users can make the code according to the codes.
Control panel coding:
The code is from left to right. The above stands for the"1", the middle stands for“X”, the bottom stands for “O”. The following code is: 0XXIX0X
Remote control coding
Open the back cover of the controller and take off the battery. You can see the code of the pad on the PCB. The code is from right to left. The first code is on the right. When the middle pad and the above pad are shorted, it stands for"0". When the middle pad and bottom pad are shorted, it stands for“l'”. Nothing stands for the "X” The following code is: 0IXXIX0X